Control Panels: Pearl 1 Loop Addressable Control Panel รุ่น PRL-LED-EN-1

     The Pearl fire alarm control panel from Notifier by Honeywell is a robust and easy to use networkable 1 or 2 loop panel. It exploits Notifier’s class leading Opal digital protocol to maximise the speed and efficiency of fire detection and alarm.

Control Panels: Pearl 2 Loop Addressable Control Panel รุ่น PRL-LED-EN

     The Pearl fire alarm control panel from Notifier by Honeywell is a robust and easy to use networkable 1 or 2 loop panel. It exploits Notifier’s class leading Opal digital protocol to maximise the speed and efficiency of fire detection and alarm.

Automatic Fire Detection: Opal Optical Smoke Detector รุ่น NFX-OPT/NFXI-OPT

     The Opal photoelectric smoke detector has a completely new detection chamber design, the result of many years of research and development. This delivers improved responsiveness, reduced sensitivity changes caused by settling dust and reduced false alarms resulting from ingress of insect and other debris. The plug-in unit uses sophisticated processing circuitry that incorporates smoothing filters to help eliminate transient environmental noise conditions that can be the cause of unwanted alarms. The devices are managed by embedded software running complex algorithms that further improve resilience to false alarms and improve detection speed.

Manual Detection: Addressable Indoor Call Point รุ่น M700KACI

     Addressable call point. M700KACI-FG supplied with Glass element. M700KACI-FF supplied with Flexible Element. Requires SR1T for surface mounting, terminal tray ETT-P and single gang back box for semi flush mounting.

Opal AV Devices: Opal Addressable Wall VAD รุ่น NFXI-WF-WC

     A high quality loop powered VAD (Visual Alarm Device) designed to alert building occupants of an emergency. Featuring fast and simple installation and control the Opal wall mount beacon is powered by the fire panel via the loop wiring. Control of the device is enabled using on-board switches or via the Opal digital protocol using the control panel. The range is installed simply by a twist fit onto the B501AP base.
     Approved to EN54-23 O class.

Interface I/O: M701 Single Output Module รุ่น M701

     The M700 series modules are designed for use with any NOTIFIER protocol fire alarm control panel and include selectable loop isolation in every device.
     The M701 control module provides a monitored single output circuit for use with polarised loads (sounder circuit) which requires a suitable power source (7Vdc - 30Vdc) for the connected load. Alternatively the same device may be placed in to an unsupervised mode which can then be used to control any switched load up to 2A @ 30Vdc.

Ancillaries: IDP-LB1 Loop Booster รุ่น 002-629

     IDP-LB1 Loop Booster boxed complete with PSU3A and space for up to 12Ah batteries.

Wireless Fire Detection: Wireless SMART3 Detector รุ่น NRX-SMT3

     Wireless Smart 3 (Optical, Thermal & Infra-Red) detector for the Notifier Agile wireless system. Powered by 4 x CR123A 3v batteries

Shopping cart